<img height="1" width="1" src="https://www.facebook.com/tr?id=3990718177617800&amp;ev=PageView &amp;noscript=1">

Roco Rescue

Roco Rescue
RescueTalk™ provides leading news and information for safety and rescue professionals and is a service of Roco Rescue, Inc., who specializes in confined space rope rescue training and rescue products for first responders in industrial rescue, municipal rescue and military rescue.
Find me on:

Recent Posts

Chad Roberson Named Interim Director of Training

Friday, March 29, 2019
“My drive is to help us get better.”
Growing up in a small northern Louisiana town, Chad Roberson admits he was “around the fire service a lot.” His father was a volunteer firefighter and from a young age, Chad understood what a life of service looked like. From age 16, Chad served as a volunteer firefighter at the same department where his father worked. After earning his bachelor’s degree from Louisiana State University, Chad became a full-time firefighter with the St. George Fire Protection District.

Chad excelled in the Fire District, working his way up to Captain, District Chief, and eventually Assistant Chief – the role he serves today. He also returned to school for two additional degrees: an associate degree in Fire Science from Louisiana State University and a Masters in Executive Fire Service Leadership from Grand Canyon University.Chad Roberson Named Interim Director of Training

Chad’s first introduction to Roco Rescue was as a student in the mid-1990s, when he took a training course funded by his fire department. After taking a few more courses, his instructors invited him to apply for a job, and he began his career journey with Roco Rescue working part-time on one of the company’s contracted safety and rescue teams.

In 2001, Chad completed an instructor development course and has been teaching for Roco Rescue ever since. In 2007, he was promoted to Chief Instructor and now serves as the Interim Director of Training.

A Career Steeped in Service
In his role at Roco Rescue, Chad draws heavily from his experience with the St. George Fire Protection District, where he leads technical rescue operations, manages vehicle, trench, structural collapse, rope, confined space, flood water, and boat rescue, as well as hazardous materials training. His exposure to technical rescue on the municipal side has benefitted his work at Roco Rescue. In his new role as Interim Director of Training he oversees all aspects of the training program, including instructor recruitment and development, curriculum updates, assessment and evaluation of both new equipment and new rescue techniques, and modifications to the Roco Training Center. He also spends a significant amount of time speaking with customers about course content, private training and custom classes.

His experience with the Fire District has also enhanced his people management skills. “When it comes down to managing people, it doesn’t matter what industry you’re in,” he says. “Management, leadership and supervision all go hand in hand. I’ve had a number of great mentors and role models, and the things I’ve learned at the fire department have been very useful to me at Roco Rescue, and vice versa.”

It is especially important, he says, to develop the ability to teach to a broad range of learning styles. “Everybody has a different learning style,” he says. “To be a successful instructor you have to understand this and be able to step back and think of different approaches; you’ve got to be versatile in your communication style and method.”

"Our instructors at Roco Rescue are especially skilled at recognizing and adapting to each student’s learning style,” says Chad, “and this is a key factor that sets us apart. It exemplifies how we care about our students and work hard to help them become great rescuers. It starts at the top, with the leadership style and the example Miss Kay sets. We treat everyone like family, whether we are training a team, doing a refresher course for a long-time customer, or providing a service at an industrial plant.”

Chad also cites the instructors’ willingness to encourage students to problem-solve and be versatile in their approach to performing a rescue, as something that differentiates Roco Rescue. “There are multiple ways to get things done,” he says. “There is no one correct way to do a rescue. But you need to make sure it’s an efficient process. We tell our students, ‘this is just one way to get it done.’ That sets us apart as a company as well.”

His “Why”
When asked why he has devoted his entire career to rescue, Chad’s answer is simple. “My drive is to help us get better,” he says.

“In Louisiana, we’ve seen so many natural disasters. And when that happens, you really see the areas for improvement and the need to help people out. Managing the incidents and being involved in process improvement to make rescues more successful and efficient – that’s my drive.”

What’s Ahead
Currently Chad’s priority is to expand Roco Rescue’s instructor base; a large part of his time is spent implementing strategies to search for and train the best of the best to join the team. He will also be playing a significant role in planning the annual Roco Rescue Challenge, a team performance evaluation in which rescuers put their skills to the test in a variety of realistic, hands-on scenarios.  

Keeping up to date on developments in rescue technology and evaluating equipment to ensure it is optimized for both comfort and safety is one of the most critical parts of his job. “Technology is driving just about every industry worldwide, and it’s no different in the rescue business or with the equipment we use,” he says. 
 
Finally, he is excited about finding new and better ways to listen to the voice of the customer in order to keep improving everything Roco does. 

Chad is trained extensively in executive leadership and planning, technical rescue operations, hazardous materials management, and more. He holds a COSS (Certified Occupational Safety Specialist) certification and a CFO (Chief Fire Officer designation). He is a certified EMT and is certified by the American Heart Association in Basic Life Support. He received accolades from the St. George Fire Protection District as Chief Officer of the Year in 2016 and a Unit Commendation Award in 2014. He is also a sought-after speaker, having presented at first responder training conferences nationwide, and his work has been published in a variety of national publications.

In his spare time, Chad enjoys spending time with his two young sons, coaching their basketball teams, and taking them on trips to visit family. He attends St. Jude Catholic Church in Baton Rouge, and he is a big fan of the LSU Tigers.

Roco Rescue Safety Officer Pat Furr Named Duane Kuehn Outstanding Safety Professional

Monday, February 25, 2019

Pat Furr, VPP Coordinator/Safety Officer and Technical Consultant for Roco Rescue, was honored last Friday with the North Dakota Safety Council's Duane Kuehn Outstanding Safety Professional award, the organization's top honor.
Roco Rescue Safety Officer Pat Furr Named Duane Kuehn Outstanding Safety Professional

Over the course of his career, Pat has worn and continues to wear a variety of hats but his favorite role, he says, is sharing what he's learned about rescue and safety with an audience through a variety of platforms, from the written word to presentations at industry conferences. "If I can communicate my experiences to those who listen, I feel I am able to keep them safe," Furr says.

Please join us in congratulating Pat on this prestigious honor


Pat Furr is a chief instructor, technical consultant, VPP Coordinator and Corporate Safety Officer for Roco Rescue, Inc. As a chief instructor, he teaches a wide variety of technical rescue classes including Fall Protection, Rope Access, Tower Work/Rescue and Suspended Worker Rescue. In his role as technical consultant, he is involved in research and development, writing articles, and presenting at national conferences. He is also a member of the NFPA 1006 Technical Rescue Personnel Professional Qualifications Standard. Prior to joining Roco in 2000, he served 20 years in the US Air Force as a Pararescueman (PJ).

Confined Space Types - Are All Your Bases Covered?

Friday, November 30, 2018

Confined Space Types - Are All Your Bases Covered?Refineries, plants and manufacturing facilities have a wide range of permit-required confined spaces – some having only a few, while others may have hundreds. Some of these spaces may be relatively open and straightforward while others are congested and complex, or at height. With this in mind, are all your bases covered? Can your rescue team (or service) safely and effectively perform a rescue from these varying types of spaces? Or, are you left exposed? And, how can you be sure?

Rescue Practice & Preplanning

With a large number of permit spaces on site, it would be impossible for a rescue team to practice in each and every one. Plus, in most cases, the spaces are operating, functioning units within the plant. Because of this, section (k) of 1910.146 allows practice from “representative” spaces. This is where the Roco Confined Space Types Chart can make the process easier.

Using OSHA guidelines for determining representative spaces, the Roco Types Chart is designed to assist employers and rescue teams plan for various types of permit spaces.

The chart allows you to categorize permit spaces into six (6) confined space types, which can then be used to prepare rescue plans, determine rescue requirements, conduct practice drills or evaluate a prospective rescue service.

First of all, it's important to note that employers are required by 1910.146 and 1926 Subpart AA to allow rescue teams the opportunity to practice and plan for the various types of confined spaces they may be required to respond. This is critical for the success of the rescue, particularly timeliness, as well as for the safety of the rescuers.

Classifying and Typing Your Spaces

So, get out your clipboard, tape measure, some sketch paper, and a flashlight (if safe to do so) in order to view as much of the interior of the space as you can. And, if you absolutely need to enter for typing and/or rescue preplanning purposes, be sure to do so using full permitting procedures. Gaining access to architectural or engineering drawings may also be helpful in determining the internal configuration when actual entry is not feasible. Armed with this information, it is time to “type” the spaces in your response area using the Roco Confined Space Types Chart.

Confined Space Types - Are All Your Bases Covered?

Over the decades, we’ve seen just about every type of confined space configuration out there. And, while there may be hundreds of permit spaces on site, most of them will fit into one of these six types and require the same (or similar) rescue plan. Of course, there are always unique situations in addition to physical characteristics, such as space-specific hazards or specialized PPE requirements, but this chart can be a valuable tool in the planning and preparation for confined space rescue operations.

We’ve also learned that it is imperative to understand the physical limitations of space access and internal configuration as well as how this affects equipment and technique choices for the rescue team. Referring to the Roco Types Chart and practicing simulated rescues from the relevant types of spaces will help identify these limitations in a controlled setting instead of during the heat of an emergency.

We can all agree that during an emergency is NOT the time to learn that your backboard or litter will not fit through the portal once the patient is packaged.

Six General Types

On the Roco Types Chart, you will note that there are six (6) general types identified, which are based on portal opening size and position of portal. Types 1 and 2 are “side” entries; Types 3 and 4 are “top” entries; and Types 5 and 6 are “bottom” entries. There are two types of each based on portal size, which is significant for rescue purposes. Openings greater than 24-inches will allow packaged patients on rigid litters or rescuers using SCBA to negotiate the opening; whereas, openings 24-inches or less will not.

Portals less than 24-inches will require a higher level of expertise and different packaging and patient movement techniques.

Once the various types have been determined, pay particular attention to spaces identified as Types 1, 3, or 5. Again, these spaces have the most restrictive portals (24-inches or less) and are considered “worst case” regarding entry and escape in terms of portal size. This is very important because it will greatly influence the patient packaging equipment and rescuer PPE that can be used in the space.

Accessibility and Internal Configuration

In addition to the “type” of the space based on portal size and location, another key consideration is accessibility or “elevation” of the portal. While the rescue service may practice rescues from Top, Side and Bottom portals – being at ground level is very different from a portal that’s at 100-ft. Here’s where high angle or elevated rescue techniques are normally required for getting the patient lowered safely to ground level.

Lastly, the internal configuration of a space must be carefully considered for rescue purposes. This will be discussed more in the following section on Appendix F.

Remember, rescue practice from a representative space needs to be a “true” representation of the kind of rescue that may be required in an emergency.

1910.146 Appendix F – Representative Spaces

In Appendix F, OSHA offers guidelines for determining Representative Spaces for Rescue Practice. OSHA adds that “teams may practice in representative spaces that are ‘worst case’ or most restrictive with respect to internal configuration, elevation, and portal size.” These characteristics, according to OSHA, should be considered when deciding whether a space is truly representative of an actual permit space.

(1) Internal Configuration

Confined Space Types - Are All Your Bases Covered?

What’s inside the space? If the interior is congested with utilities or other structural components that may hinder movement or the ability to efficiently package a patient, it must be addressed in training. For example, will the use of entrant rescuer retrieval lines be feasible? After one or two 90-degree turns around corners or around structural members, the ability to provide external retrieval of the entrant rescuer is probably forfeited. For vertical rescue, if there are offset platforms or passageways, there may be a need for directional pulleys or intermediate haul systems that are operated inside the space.

What about rescues while on emergency breathing air? If the internal configuration is so congested that the time required to complete patient packaging exceeds the duration of a backpack SCBA, then the team should consider using SAR. Will the internal configuration hinder or prevent visual monitoring and communications with the entrant rescuers? If so, it may be advisable to use an additional authorized rescuer as an “internal hole watch” to provide a communication link between the rescuers and personnel outside the space.

What if the internal configuration is such that complete patient packaging is not possible inside the space? This may dictate a “load-and-go” type rescue that provides minimal patient packaging while providing as much stabilization as feasible through the use of extrication-type short spine boards as an example.

(2) Elevation

If the portal is 4 feet or greater above grade, the rescue team must be capable of providing an effective and safe high angle lower of the victim; and, if needed, an attendant rescuer. This may require additional training and equipment. For these situations, it is important to identify high-point anchors that may be suitable for use, or plan for portable high-point anchors, such as a “man lift” or some other device.

(3) Portal Size

Confined Space Types - Are All Your Bases Covered?

Here again, the magic number is 24 inches or less for round portals or in the smallest dimension for non-round portals. It is a common mistake for a rescue team to “test drive” their 22-to-23-inch wide litter or backboard on a 24-inch portal without a victim loaded and discover that it barely fits. However, the problem arises when a victim is loaded onto the litter. The only way the litter or backboard will fit is at the “equator” of the round portal. This will most likely not leave enough room between the rigid litter or backboard and the victim’s chest, except for our more petite victims.

For rescuers, it is already difficult to negotiate a portal while wearing a backpack SCBA. For portals of 24 inches or less, it’s nearly impossible. If the backpack SCBA will not fit, it is time to consider an airline respirator and emergency escape harness/bottle instead. Warning: Do NOT under any circumstances remove your backpack SCBA in order gain access to a confined space through a restricted portal or passageway. It is just too easy for a mask to become displaced.

(4) Space Access – Horizontal vs. Vertical

Most rescuers regard horizontal retrievals as easier than vertical. However, this is not always the case. If there are floor projections, pipe work or other utilities, even just a grated floor surface, it may create an incredible amount of friction or an absolute impediment to the horizontal movement of an inert victim. In this case, the entrant rescuers may have to rely on old-fashioned arm and leg strength to maneuver the victim.

Putting the Roco Types Chart into Practice

The Roco CS Types Chart can assist by first providing a way to classify and type your different kinds of spaces. This information can then be used to design training/practice drills as well as annual performance evaluations to make sure your rescue service is capable of rescue from the varying representative spaces onsite. Of course, this applies whether you use an in-house rescue team, a contracted rescue service, or a local off-site response team. Otherwise, how do you know if you truly have your bases covered? Don’t take that chance. If an incident occurs and the rescue personnel you are depending on are not capable of safely performing a rescue, your company could be culpable.

In section (k), OSHA requires employers to evaluate the prospective rescue service to determine proficiency in terms of rescue-related tasks and proper equipment.

If you need assistance with confined space typing or rescue preplan preparation, please contact us at info@rocorescue.com or 800-647-7626.

Request your Confined Space Types Chart & Compliance Guide.

Successful Engulfment Rescue in Iowa

Monday, November 26, 2018

Successful Engulfment Rescue in IowaOur congratulations to the Burlington (Iowa) Fire Department on a successful grain bin rescue that happened in their community back in May of this year (2018). The incident was reported on Firehouse.com.

The Burlington Fire Department responded to an incident with a man trapped up to his neck inside a corn grain bin in a rural area. Upon arriving at the scene, the initial ambulance unit spoke with the victim’s son who told them that his father was buried up to his armpits inside the bin. The son had thrown a rope down to his father to prevent slipping further down into the corn. Fortunately, the victim remained calm and was able to communicate with the responders.

The bin, designed to hold up to 30,000 bushels of corn, was two thirds full on that morning.
Responders used a Res-Q-Throw Disc typically used in water rescue to lower an O2 bag with an attached non-rebreather mask to the victim.
 
As additional response vehicles arrived on scene, proper positioning of the apparatus was critical in assisting the rescue. The department’s aerial truck was positioned in a narrow lane between two grain bins and a barn where the aerial was deployed by the crew. The aerial was initially raised to the roof level where crews (two firefighters and two deputies) had assembled including the victim’s son.
To reduce weight on the roof of the structure, one of the deputies and the son came down from the structure.
Crews soon realized that the only way to rescue the gentleman was to set up a rope system and lower a responder into the bin. The aerial was put in place to assist this operation. An incident command vehicle was set up a short distance behind the aerial, offering excellent visibility to the Incident Commander.
 
Rescue equipment was gathered from various apparatus to include main and secondary life safety ropes as well as other needed gear. Pulleys were attached to the manufactured anchor points on the bottom of the aerial platform. A change-of-direction pulley was fixed to the front of the aerial truck directing the pulling action of the rope to a large grassy area in front of the truck. The main line was rigged with a 5:1 system while the secondary line was rigged with a 2:1 system. CMC MPDs were used as the descent-control device for both lines. On-scene personnel reportedly highly praised these devices.
 
A firefighter donned a Class III-harness to be lowered through a small opening in the top of the bin to the surface level of the corn, which was approximately 25 feet below. The aerial platform was positioned above the opening and remaining personnel on the room tended the lines. These personnel also assisted in lowering equipment down to the rescuer via a rope.
 
As part of the equipment being lowered were several milk crates and soda bottom flats, which became an essential part of the operation by distributing the rescuer’s weight on the corn. These crates, positioned in a horse-shoe pattern around the victim, allowed the rescuer to walk across the surface of the corn. A truck belt was lowered into the bin and was positioned around the victim’s chest. It remained attached to the secondary line to prevent the victim from slipping down further into the corn.
 
Finally, a six-paneled grain rescue tube was lowered into the bin panel by panel. Each panel was placed around the victim and then hammed into place with a TMT Rescue tool. The panels were fastened together to form a solid tube. When secured, the tube protected the victim from shifting corn and relieved some of the pressure being exert on him.
Throughout the process, the ground team kept the rescuer on a short leash to prevent him from falling into the grain himself.

A 4-gas atmospheric monitor with an extra-long sampling tube was used to test the air inside the bin to make sure the rescuer and victim were not in an IDLH atmosphere. The meter was monitored continuously throughout the rescue operation by fire personnel who was positioned on an extension ladder on the exterior of the bin near the opening. He also functioned as a safety officer for operations inside the bin and on the roof and relayed communications for the rescuer inside the space.

A neighboring fire department had brought a special grain rescue auger that was lowered into the bin. The rescuer inserted the auger inside the rescue tube and slowly removed the corn from around the victim’s chest. After the tube was secured around the victim, the IC had called for two relief cuts to be made in the bin – one cut near the victim and the other directly opposite it on the other side of the bin, which was used to empty the bin of corn. Crews used K-12 saws to cut a large triangular opening in the bin wall. The second opening was made by forcing open a door in the side of the bin near the victim. These doors, which swung inward, could only be opened after a significant amount of grain spilled from the cut made on the other side of the bin.

Local road crews which had been on site brought a large-end loader and a smaller skid loading to the scene and used them to push large amount of corn away from the openings in the walls, which enabled a continuous flow of corn.

In approximately 2-1/4 hours after crews arrived on scene, the victim was able to walk from the bin. He refused air transport but consented to ground ambulance transport where he was treated for minor injuries.

Again, our congratulations to the Burlington Fire Department as well as all the agencies involved in making this a successful rescue.

Notes:
The department noted several lessons learned which include:

• Grain bin rescue is a high hazard, low frequency event. The department recognized the importance of its training in ropes and rope operations as well as training with specialized rescue equipment.
• It was determined that the roofs of the grain bins hold far less weight than originally surmised.
• The aerial platform was a key factor in the rescue operation. It was used as an anchor point and for staging equipment. Physical limitations and maximum load-bearing capability must be carefully considered and even more especially when ropes are being utilized. Weight and angles of the aerial must be factored into the operation.

Source: www.Firehouse.com

Host a Roco Course - Get FREE Training!

Wednesday, November 14, 2018

Has your Fire Department ever thought about hosting a Roco Confined Space Rescue course?

Host a Roco Course - Get FREE Training!
It just might be easier than you think! If your municipal department needs this kind of training, and you have a training site that would be adequate – it could be that simple.

We will be offering this opportunity for up to four (4) municipal fire departments in 2019. All we ask is help from you in promoting the class to local agencies and industries so that we can get a minimum of eight (8) paying students. Then your department would receive two (2) FREE spots in the 5-day class. The more paying students, the more FREE slots your department would earn. It’s a great way to get the training you need at no cost to your organization.

Details:

One of the first things we need is to determine if you have a site that will work for the training. So, you’ll need to send us a few photos of your training site. Then, we will need a signed letter from your Fire Chief (or other authority) providing permission to conduct a Roco course at your training site and invite participants from other organizations. In turn, your department would promote the class in your local area. Roco would provide the instructors and rescue equipment at no charge to you.

If you are interesting in hosting a course next year, please email your site photos along with a letter from your Fire Chief authorizing the use of your facility for the training and for allowing other personnel to attend. Send all information to us at info@RocoRescue.com.

Note: Limited to municipal agencies within the continental United States. Class to be Level I/I-II program. All course participants must be 18 or older, physically fit, and sign waivers prior to participation.

RescueTalk™ (RocoRescue.com) has been created as a free resource for sharing insightful information, news, views and commentary for our students and others who are interested in technical rope rescue. Therefore, we make no representations as to accuracy, completeness, or suitability of any information and are not liable for any errors, omissions, or delays in this information or any losses, injuries, or damages arising from its display or use. All information is provided on an as-is basis. Users and readers are 100% responsible for their own actions in every situation. Information presented on this website in no way replaces proper training!